HCX-D191
Item
Contents
Criteria
1
Model
HCX-D191
4S-30A working current
2
Voltage
Charging voltage
16.8V
3
Current
Maximal continuous charging current
30A
Maximal continuous discharging current
30A
Current consumption
≤50μA
4
Overcharge Protection
Over charge detection voltage
4.2V~4.35V(Adjustable)
Over charge detection delay time
0.5S~2S
Over charge release voltage
4.0V~4.2V(Adjustable)
5
Over Discharge Protection
Over discharge detection voltage
2.3V~3.0V(Adjustable)
Over discharge detection delay time
50~200mS
Over discharge release voltage
2.3V~3.0V(Adjustable)
6
Over Current Protection
Over current detection voltage
0.1V~0.2V(Adjustable)
Over current detection current
Adjustable
Detection delay time
5~20mS
Release condition
Cut load,automatically recover
7
Short Circuit Protection
Detection condition
Exterior shot circuit
Detection delay time
200~500uS
Release condition
Cut load,automatically recover
8
Balance/Equilibrium
Balance voltage for single cell
4.20V±0.025V
Balance current for single cell
84mA±10mA
9
Resistance
Inner resistance
≤20mΩ
10
Temperature
Operating temperature range
0~+85°C
Storage temperature range
0~+85°C
11
Size (L*W*T)
L65mm*W65mm*T5mm