HCX-D1003
Item
Contents
Criteria (Adjustable)
1
Model
HCX-D1003 / 77905
3S-40A working current
2
Voltage
Charging voltage
12.6V
3
Current
Maximal continuous charging current
40A
Maximal continuous discharging current
40A
Current consumption
≤40μA
4
Overcharge Protection
Over charge detection voltage
4.25V±0.025V
Over charge detection delay time
0.7-1.4S
Over charge release voltage
4.05V±0.05V
5
Over Discharge Protection
Over discharge detection voltage
2.7V±0.05V
Over discharge detection delay time
1-3S
Over discharge release voltage
2.9V±0.1V
6
Discharge
Over Current Protection
(1st Protection)
Over current detection current
R=0.5mR/70
86A±10A
Detection delay time
700ms±100ms
Release condition
Cut load & charge to recover
7
Discharge
Over Current Protection
(2nd Protection)
Over current detection current
R=0.5mR/140
113A±10A
Detection delay time
180ms±50ms
Release condition (delay: 100ms)
Cut load & charge to recover
8
Short Circuit Protection
Short circuit detection current
≥365A (actual testing is needed)
Detection delay time
500us
Detection condition
Cut load/charge to recover
9
Balance
Balance voltage for single cell
4.20V±0.025V
Balance current for single cell
42±10mA
10
Temperature Protection
10KNTC B=3435
Charge Over Temp Protection
60℃±4℃
Discharge Over Temp Protection
70℃±4℃
Charge Under Temp Protection
0℃
discharge Under Temp Protection
-20℃±4℃
Temp. Protection delay
2S±1S
11
Resistance
Inner resistance P- B-
≤2.5mΩ
12
Temperature
Operating temperature range
0 ~ +85°C
Storage temperature range
0 ~ +85°C
16
Size (L*W*T)
L120mm*W65mm*T10mm
Бонус за отзыв: 20 руб. однократно для каждого товара при условии, что Вы купили этот товар (необходимо зарегистрироваться или войти)